ISO 13485 internal audit checklist, with what the FDA QMSR adds.

Ten audit areas, from design transfer to complaint handling, each with the records to sample, questions for the people doing the work, red flags and ISO 13485:2016 clause numbers. Each area notes what 21 CFR Part 820 adds for devices marketed in the US.

Last verified November 11, 2026

Works for
ISO 13485:2016, the current edition and the one the QMSR incorporates by reference.
Organized by
Area, the way an auditor walks a site. ISO 13485 is copyrighted, so clauses appear as numbers only.
Cost
Nothing. The checklist needs no email. The fillable Excel toolkit is free too; we ask for your name, company and email.
To print

What clause 8.2.4 asks of your audit program

ISO 13485 puts internal audit in clause 8.2.4. In our words, a certification auditor will look for:

  • A documented procedure setting out who plans, conducts, records and reports audits.
  • A program based on risk and history: how much each process matters, how it is performing, and what earlier audits found.
  • A recorded basis for each audit: what it is measured against, what it covers, how often it happens and how it is done.
  • Objective auditors who do not audit their own work.
  • Records of each audit: what was covered, what was found and what the auditor concluded.
  • Prompt action by the managers of the area audited, then a follow-up that checks the actions were taken and reports what it found.

No clause sets a frequency. Rate each process on risk to patients and users, regulatory exposure, complexity, recent problems and recent change, and audit the higher-rated ones more often. A defensible default: every process once a year. New to the subject? Start with our glossary entry on internal audit.

How to sample

Every audit is a sample; certification audit reports must say so. How you sample sets what your conclusions are worth.

  • Define the population: every complaint, lot, design change or CAPA since the last audit.
  • Pick the sample yourself. A sample the auditee hands you is a showcase.
  • Spread it across shifts, device families, people, and old and recent records.
  • Start small, then expand. Start with three to five records. When one fails, take more: that tells a slip from a system failure.
  • Trace both ways: from a complaint back to the lot, its components and its release, and from a supplier change forward to the devices it reached.
  • Record what you sampled, by ID, so anyone can find it again.

Free download · Excel + PDF

Get this checklist in Excel, plus the rest of your audit program

The ISO 13485 Internal Audit Toolkit: this checklist as an 18-sheet Excel workbook and a 20-page printable PDF, plus what goes around it.

  • A 12-month audit program and a one-page audit plan
  • A clause checklist: 77 checks across clauses 4 to 8, with a column for what 21 CFR Part 820 adds
  • Ten area checklists with result drop-downs, from design transfer to training
  • A findings log that flags overdue corrective actions
  • A dashboard that totals findings and results by sheet, and a one-page report for management review

Excel (.xlsx, no macros) and PDF. Free to use and adapt inside your organization. Not affiliated with ISO or FDA; it does not reproduce the standard.

Preview of the ISO 13485 toolkit PDF cover
Preview of a toolkit area checklist page with evidence, questions, red flags and the US QMSR note

Fields marked * are required.

We use your details to give you this download and may follow up personally by email from info@glocalinsight.com. Updates only if you tick the box. We never sell your details or share them for anyone else's marketing. See our privacy policy.

What the QMSR adds to ISO 13485

FDA's Quality Management System Regulation took effect on February 2, 2026. It amends 21 CFR Part 820 and incorporates ISO 13485:2016 by reference, so for a US manufacturer the clauses above are also the regulation. Part 820 then adds a short list of US requirements. Our summary:

Part 820What it addsISO 13485 clauses
21 CFR 820.1Scope: finished-device manufacturers. Does not apply to manufacturers of components or parts. Where ISO 13485 conflicts with the FD&C Act or FDA's regulations under it, the Act and those regulations control.Whole system
21 CFR 820.3Definitions. Using "safety and performance" does not reduce the obligation to provide reasonable assurance of safety and effectiveness.Whole system
21 CFR 820.10(b)UDI under Part 830; tracking under Part 821 where it applies; reporting under Part 803; corrections and removals under Part 806.7.2.3, 7.5.8, 7.5.9.1, 8.2.3, 8.3.3
21 CFR 820.10(c)Design and development applies to class II and III devices and to listed class I devices (software-automated plus five device types).7.3
21 CFR 820.10(d)Implantable-device traceability also applies to devices that support or sustain life and whose failure, when used as labeled, could reasonably be expected to cause significant injury.7.5.9.2
21 CFR 820.35Content of complaint, servicing and UDI records; records may be marked confidential.4.2.5, 7.5.4, 7.5.8, 7.5.9, 8.2.2
21 CFR 820.45Labeling and packaging: procedures, accuracy check before release or storage, documented release, and documented inspection before use to prevent mix-ups.7.5.1
FDA QMSR FAQFDA can inspect management review, quality audit (internal audit) and supplier audit reports; the former 820.180(c) exception is gone.5.6, 7.4, 8.2.4

One change matters most to an internal audit program. The old regulation excepted internal audit reports from FDA inspection (former 21 CFR 820.180(c)). FDA now states that the QMSR gives it “the authority to inspect management review, quality audits, and supplier audit reports.” Write every report and finding as a record someone outside the company will read.

FDA does not require or issue ISO 13485 certificates, and a certificate does not exempt a manufacturer from inspection. Where certification fits, and what it costs, is in our ISO 13485 certification cost guide.

Who reads your internal audits

Accredited certification bodies work to ISO/IEC 17021-1:2015, and since February 2026 FDA can read the reports too.

  • Initial certification. Stage 1 checks that internal audits and management reviews are planned and performed, and Stage 2 includes both.
  • Every certification audit report. It must summarize the evidence on your internal audit and management review process.
  • Every surveillance audit. Internal audits and management review head the list of what each must include.
  • FDA inspections. Management review, quality audit and supplier audit reports are no longer exempt from inspection under the QMSR.

If an outside auditor finds in two days what your program missed in a year, expect questions about the program itself. Our internal auditor training covers sampling and writing findings, and our ISO 13485 consulting builds the system the audits test, with the QMSR additions built in.

Common questions

What should an ISO 13485 internal audit checklist include?

The records to sample, the questions to ask the people doing the work, and the conditions that would be findings, for each process in scope, with the clause numbers and the regulatory requirements of your markets. For a US manufacturer that means the additions in 21 CFR Part 820 as well as the ISO 13485 clauses.

How often do ISO 13485 internal audits have to be done?

Clause 8.2.4 asks for audits at planned intervals, under a program that reflects how much each process matters, how it is performing and what earlier audits found. It sets no fixed frequency. A defensible default is every process in scope once a year, with processes that carry more risk to patients or have a history of problems audited more often.

Who can perform an ISO 13485 internal audit?

Anyone competent who does not audit their own work: a trained employee from another department, a colleague from another site, or an outside auditor. ISO 13485 requires a documented internal audit procedure, and certification auditors check that your auditors were objective and competent.

Can FDA see our internal audit reports under the QMSR?

Yes. FDA states that the QMSR gives it the authority to inspect management review, quality audit and supplier audit reports, and that the exceptions in the former 21 CFR 820.180(c) were not carried over. Write reports and findings as factual records, and close the loop on each finding.

Does FDA require ISO 13485 certification?

No. Since February 2, 2026, 21 CFR Part 820 incorporates ISO 13485:2016 by reference, so a US manufacturer has to meet the standard's requirements, but FDA does not require or issue ISO 13485 certificates, and a certificate does not exempt a manufacturer from inspection.

Should the internal audit cover 21 CFR Part 820 as well as ISO 13485?

If you market devices in the US, yes. Part 820 adds requirements for labeling and packaging and for complaint, servicing and UDI records, makes design controls mandatory for class II and III and some class I devices, and ties several clauses to other FDA rules: medical device reporting (Part 803), corrections and removals (Part 806), tracking (Part 821) and unique device identification (Part 830). Put them in the audit criteria for the processes they touch.

Do we need an internal audit before the certification audit?

Yes. Under ISO/IEC 17021-1, Stage 1 must evaluate whether internal audits and management reviews are being planned and performed, and Stage 2 includes both. Every surveillance audit reviews them again.

Sources

Changelog

  • 2026-11-11 — Published, with the free ISO 13485 Internal Audit Toolkit (Excel and PDF). QMSR notes checked against 21 CFR Part 820 on eCFR and FDA's QMSR FAQ. ISO's page for ISO 13485:2016 checked: last reviewed and confirmed in 2025, still current.