Skip to content

Free tool · Runs in your browser

ISO 13485 audit days calculator for medical device quality systems.

Enter your headcount and scope and see, as you type, how many auditor days your ISO 13485 certification audits are likely to take: the initial audit, each surveillance audit and recertification, alone or with ISO 9001. Nothing you enter is sent anywhere.

Last verified November 13, 2026

Covers
ISO 13485, alone or with ISO 9001, under accredited certification.
Based on
Global ACI-TECH-3-007 (M) (opens in a new tab), the Global ACI document that carries IAF MD 9:2023 forward.
Privacy
Your numbers stay in your browser. No email, no sign-up.

Estimate your ISO 13485 audit days

People within the scope

Count everyone whose work falls within the scope of the certificate, on every shift. We convert part-time staff to full-time equivalents at 40 hours a week.

What the certificate covers
Audited with ISO 9001?

Integrated or combined in one visit, at least 25% is added to the ISO 13485 time.

Sites

Your estimate

Enter the number of people within the scope to see your estimate.

This is an estimate, not a quote. Your certification body determines the audit time for your organization and must be able to justify it, starting from the same rules this calculator uses. Time for regulatory requirements, such as MDSAP jurisdictions, is added on top.

For ISO 9001, ISO 14001 and ISO 45001, use our ISO audit days calculator; for information security, our ISO 27001 audit days calculator.

How ISO 13485 audit time is worked out

Accredited certification bodies do not choose audit time freely. For ISO 13485 they follow Global ACI-TECH-3-007 (M) (opens in a new tab), issued July 10, 2026, and applied from August 28, 2026, which carries IAF MD 9:2023 forward without substantive change, together with the general audit-time rules in Global ACI-TECH-3-004 (M) (opens in a new tab). In outline:

  1. Its own starting figures. ISO 13485 does not use the ISO 9001 figures. Accredited certification bodies start from the medical device table in Global ACI-TECH-3-007, which gives the days for the initial audit, Stage 1 and Stage 2 together, against the effective number of people within the scope. For the same headcount it starts well above ISO 9001, because a device quality system carries risk management, design controls, sterilization and supplier controls that the auditor has to cover.
  2. Effective personnel. Everyone whose work falls inside the scope of the certificate counts, on every shift: permanent, temporary and part-time people, counted as full-time equivalents. People outside the scope do not count, which is why the scope statement is the first real decision.
  3. Adjustments. Time goes up for more than one main technical area, complex devices, critical outsourced processes or parts, installation at customer sites, poor regulatory compliance and multiple shifts or production lines. Reductions are narrower than for ISO 9001: together they cannot take the time more than 20% below the starting figure, and they are limited to a scope without manufacturing (wholesale, retail, transport or equipment maintenance) or a smaller product range or process since the last audit. A scope of distribution or transportation services only can be up to 50% lower.
  4. Regulatory requirements on top. Time to audit national or regional regulatory requirements, and any dossier review, is added to the ISO 13485 time rather than taken out of it. Where higher-risk devices are involved, Stage 1 should take place on site.
  5. With ISO 9001. If ISO 9001 and ISO 13485 are audited together, integrated or combined, at least 25% is added to the ISO 13485 time.
  6. Sites. Sites that design, develop or manufacture devices cannot be sampled: each one is audited. Other sites with the same activities, such as distribution or service locations, can be sampled under the general multi-site rules.
  7. After certification. Surveillance audits in years one and two each take about a third of the initial audit time, and rarely less than a day. Recertification takes about two thirds of the time a fresh initial audit would need, recalculated from your scope at the time.

What makes ISO 13485 audit time go up or down

Likely to add time

  • More than one main technical area, for example active and non-active devices
  • Complex devices, or sterile devices and the sterilization process
  • Suppliers of critical processes or parts, including own-label products
  • Installing devices at customer sites
  • A record of poor regulatory compliance
  • Multiple shifts or production lines

Can reduce time (20% limit in total)

  • A scope without manufacturing: wholesale, retail, transport or equipment maintenance
  • A smaller product range since the last audit
  • Fewer design or production processes since the last audit
  • Distribution or transportation services only (up to 50% lower)

As with any standard, the biggest lever is the scope. Time follows the people inside the scope of the certificate, so a scope drawn wider than your device activities need carries extra audit time through the whole three-year cycle.

Checking a certification quote

Two accredited certification bodies looking at the same device company should start from the same figure. Ask each for the effective personnel it counted, the technical areas it assumed, every adjustment and its reason, and any time added for regulatory requirements. A quote far below this estimate usually counts fewer people, applies more than the 20% reduction allowed, or leaves out a site that cannot be sampled.

For the full budget, including the day rate, regulatory requirements and consulting, see our ISO 13485 certification cost guide. Getting ready for the audit? Our free ISO 13485 internal audit checklist covers design transfer to complaints and CAPA.

Common questions

How many audit days does ISO 13485 certification take?

It depends mainly on the effective number of people within the scope of the certificate, then on adjustments for device complexity, technical areas, critical suppliers, shifts and regulatory requirements. For the same headcount it starts well above ISO 9001. Enter your numbers in the calculator above for the initial audit, each surveillance audit and recertification.

Why does ISO 13485 take longer to audit than ISO 9001?

Because accredited certification bodies use a separate, higher set of starting figures for medical device quality systems, set in Global ACI-TECH-3-007 (formerly IAF MD 9). The auditor has to cover risk management, design controls, process validation, sterilization where it applies, supplier controls and regulatory reporting, none of which an ISO 9001 audit has to reach.

Can the certification body reduce ISO 13485 audit time?

Only a little. Reductions together cannot take the time more than 20% below the starting figure, against 30% for ISO 9001, and they are limited to a scope without manufacturing or a smaller product range or process since the last audit. A scope of distribution or transportation services only can be up to 50% lower. Every reduction has to be justified.

How much extra time does ISO 9001 add to an ISO 13485 audit?

At least 25% on top of the ISO 13485 time, whether the two are audited as an integrated system or combined in one visit. More can be needed where the scopes or the people covered differ.

Can sites be sampled for ISO 13485?

Not where they design, develop or manufacture devices: each of those sites is audited. Other sites with the same activities, such as distribution or service locations, can be sampled under the general multi-site rules, with the central function audited each time.

Does the calculator include MDSAP or FDA requirements?

No. Time to audit national or regional regulatory requirements is added to the ISO 13485 time, and MDSAP sets audit time by its own procedure. An FDA inspection under the Quality Management System Regulation is separate from certification and is not shortened by a certificate.

We help device manufacturers and suppliers build and certify ISO 13485 quality systems, including the FDA QMSR. Comparing advisers? See how to choose an ISO 13485 consultant, or talk to us about yours.

Sources

This page draws on Global ACI publications, used with acknowledgment. Our conventions, not requirements: part-time hours are converted at 40 hours a week; each headcount takes the figure for its whole size range; above the published range the estimate continues the progression; day figures are rounded to the nearest half day. Our Global ACI page explains the move from IAF.

Changelog

  • 2026-11-13 — Published. Checked against Global ACI-TECH-3-007 (M), TECH-3-004 (M) and TECH-3-001 (M), version 1.0 of each, issued July 10, 2026, and applied from August 28, 2026.