ISO 45001 · Wichita, KS
ISO 45001 consulting for the paint hangar.
Wichita paints aircraft, and OSHA's hexavalent chromium standard has an exception written for exactly that work. It covers one task, not the whole paint shop.
We are an active member of the Wichita Manufacturers Association, and we work on site in Wichita whenever the work calls for it. If you see us at a WMA meeting, please come and introduce yourself. We would love to get to know you and your business.
One exception, written for aircraft painting
The Wichita hub page is about the aerospace certificate a supplier needs to win the work. This page is about what that work does to the people in the paint hangar, and about one federal rule that treats aircraft painting differently from every other trade.
OSHA's Chromium (VI) standard, 29 CFR 1910.1026, sets a permissible exposure limit of 5 micrograms per cubic meter as an 8-hour average. Employers must reach it with engineering and work practice controls wherever those are feasible. Chromium compounds go into aircraft paints and primers for corrosion protection, so the rule bites hard in aerospace. One paragraph carves out an exception: where aircraft or large aircraft parts are painted in the aerospace industry, controls only have to bring exposure down to 25 micrograms, and respirators make up the rest.
The exception is narrow. OSHA reads “aircraft or large aircraft parts” as the interior or exterior of an assembled aircraft, plus wings, tail sections, control surfaces and comparably sized parts. In a 2018 interpretation letter it said the paragraph does not cover paint removal on aircraft, or any work on ground support equipment. Smaller parts painted in a booth fall under the general rule, and OSHA's aerospace fact sheet says a downdraft or cross-draft booth can keep exposures below the limit.
One Wichita building can hold all three jobs: final paint on an assembled aircraft, sanding and stripping during completions or maintenance, and priming small parts in a booth. Each falls under a different paragraph with a different control target. A hazard register that lists “chromate exposure, painting” once, with respirators as the control, has stretched the aerospace exception over work it does not cover. The first step is a task list, with each task assigned to the paragraph that governs it.
ISO 45001 then adds a second test. Clause 8.1.2 asks for controls chosen in order of preference: elimination, substitution, engineering, administrative measures, and protective equipment last. The federal rule makes respirators lawful for large-part painting. The standard still asks whether a chromate-free or lower-chromate coating was considered first, and OSHA's fact sheet recommends both where performance allows.
Where the coating is called out in your customer's specification, the substitution decision is not yours alone. Ask the customer, and record the question, the answer and the date. A certification auditor can test that record. A note saying chromate is required, with nothing behind it, does not pass.
The manufacturing base here
The Wichita metro has 609 manufacturing establishments, and 87% of them employ fewer than 100 people (530 of them, per US Census County Business Patterns, 2023). That puts it 82nd by small-manufacturer base among the 194 US markets we cover.
Wichita has 107 aerospace product and parts establishments, about 16 times the national concentration, and roughly 30,400 aerospace manufacturing jobs. In Wichita, growing a machine shop usually means growing into an aerospace program, and the program arrives with AS9100.
Which safety regulator applies
Kansas is not an OSHA-approved State Plan and is under federal OSHA jurisdiction, which covers most private-sector workers in the state.
What an engagement covers
- Chromium (VI) task inventory Every task that sprays, sands, blasts or strips a chromate coating, assigned to the paragraph of 29 CFR 1910.1026 that governs it: the aircraft painting exception, the general limit, or maintenance and repair.
- Exposure determination calendar Monitoring at least every six months at or above the action level and every three months above the limit, with results to employees within 15 work days. Each date has an owner.
- Substitution review, on the record A documented look at chromate-free and lower-chromate coatings for each task, including the questions put to customers whose specifications set the coating. See ISO 45001.
- Respirators as a planned control Where the aircraft painting exception applies, respirators are part of the design. We check fit, selection and change-out against the exposures you actually measured, not the ones you expect.
- Internal audit of the paint operation Auditor-grade internal audits that walk the hangar and the booth against ISO 45001 and the chromium standard together, before the certification body does.
Questions we get from Wichita companies
Does OSHA's aircraft painting exception cover our Wichita paint shop?
Only part of it, most likely. The exception covers painting assembled aircraft, inside or out, and large parts such as wings, tail sections and control surfaces. For that work, controls must reach 25 micrograms per cubic meter, and respirators bring exposure to the 5 microgram limit. OSHA's 2018 interpretation excludes paint removal and all ground support equipment. Small parts painted in a booth are held to the general limit.
We strip and repaint aircraft in Wichita. Which chromium rule applies to the stripping?
The general one. OSHA has said the aircraft painting exception does not apply to paint removal, so blasting or sanding a chromate coating has to meet the 5 microgram limit through feasible engineering and work practice controls. OSHA accepts that controls may not be feasible during some maintenance and repair work. There, you still use every feasible control and add respirators. Your ISO 45001 hazard register should show which case each task is, and why.
Can an aerospace painter in Kansas certify to ISO 45001 with respirators as the main control?
Yes, for the tasks where the federal rule allows it, but the system has to show its reasoning. Clause 8.1.2 puts substitution and engineering ahead of protective equipment. The auditor will look for evidence that chromate-free or lower-chromate coatings were considered, and that controls were pushed as far as the rule requires. Where a customer specification sets the coating, keep the question and the customer's answer on file.
What chromium records will an ISO 45001 auditor expect to see?
The ones the federal standard already requires, kept as evidence of compliance under clause 9.1.2. That means exposure determinations for each exposed employee, periodic monitoring at the required frequency, written notice of results within 15 work days, and the corrective action whenever results exceed the limit. It also means regulated areas where exposure can exceed the limit, and medical surveillance for anyone at or above the action level for 30 or more days a year.
More in Wichita
Our Wichita page leads with AS9100 and carries the local research this page builds on.
Nationwide: ISO 45001 consulting services.
Also in Wichita: ISO 9001, ISO 14001, ISO 27001.
ISO 45001 elsewhere: Nashville, Rockford.
Nearby metros: Kansas City, MO; Tulsa, OK; Oklahoma City, OK; Topeka, KS.