Skip to content

Tracker · re-checked monthly

Building performance standards, city by city.

Cities and states now cap the energy use or emissions of large buildings, with dated deadlines and real penalties. This tracker covers fifteen jurisdictions, each checked against the government's own pages, last on November 20, 2026, and explains where ISO 14001 and ISO 50001 fit.

Last verified November 20, 2026

The laws

WhereLawWho is coveredWhat it requiresKey datesPenalties
New York City Local Law 97 of 2019 (NYC Admin. Code §28-320 and §28-321)Buildings over 25,000 sq ft, and tax lots or condominium groups whose buildings together exceed 50,000 sq ft.Annual greenhouse gas emissions limits per building. Reports under Article 320 are certified by a registered design professional.Compliance periods 2024–2029, 2030–2034, 2035–2039, 2040–2049; carbon neutral by 2050. Limits tighten in 2030. Next annual report due May 1, 2027.$268 per metric ton of CO2e over the limit; failure to file, $0.50 per gross sq ft per month for up to 12 months.
Boston BERDO 2.0 (City of Boston Code, Ch. VII, §7-2.2)Non-residential buildings of 20,000 sq ft or more; residential buildings with 15 or more units or 20,000 sq ft or more; qualifying multi-building parcels.Annual energy and water reporting, third-party data verification (2026, then every five years) and emissions standards that step down every five years to net zero in 2050.Standards apply from 2025 to buildings of 35,000 sq ft or 35 units and up, and from 2030 to smaller covered buildings. 2026 data due May 15, 2027.Failure to report $150 to $300 a day; failure to meet standards $300 to $1,000 a day; alternative compliance payment $234 per ton of CO2e.
Washington, DC Building Energy Performance Standards (D.C. Code §8-1772.21)Cycle 1: private buildings of 50,000 sq ft or more and District-owned buildings of 10,000 sq ft or more. Private buildings of 25,000 sq ft or more from 2029, and 10,000 sq ft or more from 2035.An energy performance standard, at least the District median ENERGY STAR score for each property type. Buildings below it must improve within the cycle.Cycle 1 ends December 31, 2026. Under the code as amended October 2, 2026, Cycle 2 starts in 2029 and Cycle 3 in 2035.Alternative compliance payments set by DOEE; civil fines and enforcement by the Attorney General are authorized.
Atlanta Commercial Buildings Energy Efficiency Ordinance (Atlanta Code of Ordinances, Part III, Ch. 2, Art. J, §§8-2222 to 8-2237; Ord. 2015-16)City-owned properties and private (non-city) properties of 25,000 sq ft or more, with exceptions for buildings without occupancy, mostly residential or lodging buildings without whole-building data, and financial hardship.Annual benchmarking and public disclosure (for buildings with an ENERGY STAR score of 55 or more), plus an energy and water audit every ten years. Retro-commissioning is currently optional.Benchmarking due June 1 each year for the previous calendar year. Audit summary reports due December 31 every ten years, in the year matching the last digit of the Atlanta Building ID.Not set out in Article J; records must be kept three years (bills) and eleven years (audit reports).
Philadelphia Building Energy Performance Program (Bill No. 190600; Phila. Code Title 9)Non-residential buildings of 50,000 sq ft or more, including hotels and industrial buildings.Every five years: a tune-up by a certified specialist, a high-performance building certification, or an exemption. No emissions limits.Tune-up reports due September 30, 2026 (over 200,000 sq ft), September 30, 2027 (100,000–200,000), October 2, 2028 (70,000–100,000) and October 1, 2029 (50,000–70,000).$2,000 for a missed deadline, plus $500 a day starting 30 days after it.
Chicago Chicago Energy Benchmarking Ordinance (Municipal Code ch. 18-14)Commercial, institutional and residential buildings of 50,000 sq ft or more.Annual benchmarking and public disclosure, with data verification every three years. No mandatory investments.Reports due June 1 every year.Up to $100 for a first violation, plus up to $25 a day while it continues.
Denver Energize Denver Building Performance Policy (ordinance passed 2021; Rules and Regulations effective August 27, 2026)Commercial and multifamily buildings of 5,000 sq ft or more: small buildings 5,000–24,999 sq ft and large buildings 25,000 sq ft and up, with different requirements.An energy efficiency requirement: benchmarking and energy use (EUI) performance targets for large buildings, prescriptive requirements for small ones, with timeline extensions and alternate compliance options. Compliance status must be disclosed when a building is sold.Timelines are set in the Rules and Regulations (latest effective August 27, 2026).Notice of violation, a 90-day cure period, then an administrative citation with civil penalties.
Colorado Building Performance Colorado (Colorado Energy Office; enforced by CDPHE's Air Pollution Control Division)Most commercial buildings of 50,000 sq ft or more.Annual benchmarking plus building performance standards toward statewide cuts in commercial building emissions of 7% by 2026 and 20% by 2030 against 2021. Meeting Energize Denver counts as meeting the state targets for Denver buildings.Benchmarking report and fee due November 1 each year. Pathway changes without documentation until November 1, 2028; target adjustments by December 31, 2029; 2030 pathway adjustments by January 31, 2031.Enforcement by CDPHE; late reports and fees are subject to penalties.
Seattle Building Emissions Performance Standard (Seattle Municipal Code 22.925)Nonresidential and multifamily buildings over 20,000 sq ft.Greenhouse gas intensity targets that tighten every five years to net zero between 2041 and 2050, plus verified benchmarking and GHG reports.First verification and GHG reports October 1, 2027 (over 90,000 sq ft) through 2030 (20,000–30,000 sq ft); first targets 2031 to 2035 by size.Up to $10 per sq ft (nonresidential) or $7.50 (multifamily) per five-year interval; reporting failures up to $15,000.
Washington State Clean Buildings Performance Standard (RCW 19.27A.210; WAC 194-50)Tier 1: nonresidential buildings over 50,000 sq ft. Tier 2: 20,000–50,000 sq ft, plus multifamily of 50,000 sq ft or more.Benchmarking, an energy management plan and an operations and maintenance program for both tiers; Tier 1 must also meet an energy use target or an approved pathway.Tier 1 reports June 1, 2026 (over 220,000 sq ft), June 1, 2027 (90,000–220,000) and June 1, 2028 (50,000–90,000), then every five years. Tier 2 reports July 1, 2027.Tier 1 up to $5,000 plus $1.50 per sq ft; Tier 2 up to $0.30 per sq ft.
Los Angeles Existing Buildings Energy and Water Efficiency (EBEWE), LAMC Ch. IX, Art. 1, Div. 97Privately owned buildings of 20,000 sq ft or more.Annual energy and water benchmarking, plus an audit and retro-commissioning every five years. No performance targets.Benchmarking due June 1. Audits and retro-commissioning due December 1 by the last digit of the building ID: 0–1 in 2026, 2–3 in 2027.$202 non-compliance fee plus late charges and interest.
San Francisco Existing Buildings Energy Performance Ordinance (Environment Code ch. 20)Nonresidential buildings of 10,000 sq ft or more; multifamily of 50,000 sq ft or more.Annual benchmarking and, for nonresidential buildings, an energy audit every five years. A separate ordinance requires 100% renewable electricity for commercial buildings of 50,000 sq ft or more by December 31, 2030.Benchmarking due May 1 each year. Renewable electricity by December 31, 2030.Up to $100 a day (50,000 sq ft and over) or $50 a day, for at most 25 days a year.
St. Louis Building Energy Performance Standard (Ordinance 71132)Buildings of 50,000 sq ft or more.Energy use targets by property type, reset each four-year cycle (six years for houses of worship and qualified affordable housing).Cycle 2 targets published May 2026; compliance due May 1, 2030.Fines, liens or loss of occupancy permits; benchmarking failures $50 to $200 a day, capped at $1,000 a year.
Maryland Building Energy Performance Standards (Climate Solutions Now Act of 2022; COMAR 26.28; amended by HB 49 of 2025)Buildings of 35,000 sq ft or more, excluding parking garages. Buildings in Montgomery County follow the county program from October 1, 2025.Annual benchmarking (third-party verified in 2026); direct emissions standards from 2030, reaching net zero in 2040. MDE intends to adopt an energy use standard in 2027.Benchmarking due June 1 each year; emissions standards from 2030.Alternative compliance payments at the social cost of carbon; $100 annual reporting fee.
Montgomery County, MD Building Energy Performance Standards (County Code Ch. 18A, Art. 6; Bill 16-21)Buildings of 25,000 sq ft or more.Interim and final energy use standards, or an approved building performance improvement plan.Interim evaluation years 2028, 2030 or 2031 and final 2033, 2035 or 2036, by building group.Class A civil violation: $500, then $750.

Square footage is gross floor area as each law defines it. Penalties are as each jurisdiction states them; check the code for exemptions, adjustments and appeals.

Where ISO 14001 and ISO 50001 fit

  • The law becomes a managed obligation. ISO 14001 requires you to identify compliance obligations (clause 6.1.3), plan action on them and evaluate compliance (clause 9.1.2). A building performance standard with a reporting date and a penalty belongs on that register, with an owner.
  • The data gets controlled. Benchmarking, third-party verification and emissions reports all depend on meter data, utility bills and floor areas being right. A management system gives those records owners, checks and retention.
  • The improvement gets planned. Where a law sets a target, ISO 50001's energy review, baseline and energy performance indicators are the same arithmetic. ISO 14001 objectives can carry the target into budgets and projects.
  • The audit checks it. A certification audit samples how you met your obligations, so a missed filing surfaces internally first. Our ISO 14001 internal audit checklist includes compliance evaluation.

Moving to the new edition? See our ISO 14001:2026 transition tracker and the ISO 14001:2026 gap analysis checklist. For the cost of certification, see the ISO 14001 cost guide.

Common questions

Does ISO 14001 certification satisfy a building performance standard?

No. None of the laws on this page accepts ISO 14001 certification as compliance. Each sets its own metric, such as emissions per square foot, an ENERGY STAR score or a tune-up, and its own reporting. What ISO 14001 adds is the system around the obligation: clause 6.1.3 makes the law a compliance obligation with an owner, clause 9.1.2 requires you to evaluate compliance, and the certification audit checks that you do.

Is ISO 50001 more relevant than ISO 14001 here?

For energy performance targets, often yes. ISO 50001 is the energy management standard, built around an energy review, baselines and energy performance indicators, which is the arithmetic most of these laws use. ISO 14001 covers the wider set of environmental aspects and legal obligations. Organizations with large buildings and plants frequently run both in one integrated system.

Which cities set emissions limits rather than benchmarking?

Of the jurisdictions on this page, New York City, Boston and Seattle set greenhouse gas limits or intensity targets, and Maryland's direct emissions standards start in 2030. Washington, DC, Denver, St. Louis, Montgomery County and Washington State set energy performance standards, and Colorado sets statewide emissions reduction targets for 2026 and 2030. Philadelphia requires periodic tune-ups. Chicago, Atlanta, Los Angeles and San Francisco require benchmarking and, in Atlanta, Los Angeles and San Francisco, audits.

Do these laws apply to manufacturing plants?

Often. Most cover buildings by floor area, not use. Philadelphia's program names industrial buildings, Boston and New York count most building types above their size thresholds, and Seattle and Washington State cover nonresidential buildings. Check the covered-buildings list each city publishes and the exemptions in the code.

Sources

Changelog

  • 2026-11-20 — Added Atlanta, from Article J of the City of Atlanta Code of Ordinances (version October 21, 2026).
  • 2026-11-19 — Added Denver (Energize Denver) and Colorado (Building Performance Colorado), from the city's and the Colorado Energy Office's pages.
  • 2026-11-19 — Published. Twelve jurisdictions, each checked on the city's or state's own pages or code on November 19, 2026. DC's second cycle shown as starting in 2029, as amended October 2, 2026.

Information, not legal advice. Confirm how a law applies to you with counsel.